Remote northern communities of Nunavik rely on fossil fuels for space heating and domestic hot water production. The capital Kuujjuaq is characterized by 8500 heating degree days and discontinuous permafrost. Numerical simulations taking into account latent heat effects due to water-ice phase changes demonstrated that the 10-year performance of small-diameter borehole heat exchangers is as valuable as conventional diameters. Moreover, owing to the cold underground, deeper boreholes perform significantly better than shallow ones. A heat extraction rate of 35 W m-1 can be sustainably maintained by a 300-m borehole. The financial analysis showed that ground-source heat pumps are a viable alternative to fossil fuels. Absorption heat pump is the most interesting technology, but only district-scale applications could justify high drilling and installation costs of vertical ground heat exchangers. Payback time of 15 years was found at the current costs, but less than 10 years can be achieved at 150 CAD m-1 drilling cost.

Efficiency evaluation of borehole heat exchangers in Nunavik, Québec, Canada

Giordano N.
;
Mandrone G.;
2019-01-01

Abstract

Remote northern communities of Nunavik rely on fossil fuels for space heating and domestic hot water production. The capital Kuujjuaq is characterized by 8500 heating degree days and discontinuous permafrost. Numerical simulations taking into account latent heat effects due to water-ice phase changes demonstrated that the 10-year performance of small-diameter borehole heat exchangers is as valuable as conventional diameters. Moreover, owing to the cold underground, deeper boreholes perform significantly better than shallow ones. A heat extraction rate of 35 W m-1 can be sustainably maintained by a 300-m borehole. The financial analysis showed that ground-source heat pumps are a viable alternative to fossil fuels. Absorption heat pump is the most interesting technology, but only district-scale applications could justify high drilling and installation costs of vertical ground heat exchangers. Payback time of 15 years was found at the current costs, but less than 10 years can be achieved at 150 CAD m-1 drilling cost.
2019
25th IIR International Congress of Refrigeration, ICR 2019
can
2019
2019-
4381
4388
Feflow; Freeze-thaw Cycles; Ground-source Heat Pumps; Nunavik; Permafrost
Giordano N.; Riggi L.; della Valentina S.; Casasso A.; Mandrone G.; Raymond J.
File in questo prodotto:
File Dimensione Formato  
92_19_quebec.pdf

Accesso riservato

Tipo di file: PREPRINT (PRIMA BOZZA)
Dimensione 693.25 kB
Formato Adobe PDF
693.25 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1768973
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact