Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto INSERISCI in fondo alla pagina
CINECA IRIS Institutional Research Information System
To obtain direct measurements of the muon content of extensive air showers with energy above 101 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m close to the intersection of the shower axis with the ground to much less than one per m when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.
Calibration of the underground muon detector of the Pierre Auger Observatory
Aab A.;Abreu P.;Aglietta M.;Albury J. M.;Allekotte I.;Almela A.;Alvarez-Muniz J.;Alves Batista R.;Anastasi G. A.;Anchordoqui L.;Andrada B.;Andringa S.;Aramo C.;Araujo Ferreira P. R.;Arteaga Velazquez J. C.;Asorey H.;Assis P.;Avila G.;Badescu A. M.;Bakalova A.;Balaceanu A.;Barbato F.;Barreira Luz R. J.;Becker K. H.;Bellido J. A.;Berat C.;Bertaina M. E.;Bertou X.;Biermann P. L.;Bister T.;Biteau J.;Blazek J.;Bleve C.;Bohacova M.;Boncioli D.;Bonifazi C.;Bonneau Arbeletche L.;Borodai N.;Botti A. M.;Brack J.;Bretz T.;Brichetto Orchera P. G.;Briechle F. L.;Buchholz P.;Bueno A.;Buitink S.;Buscemi M.;Caballero-Mora K. S.;Caccianiga L.;Canfora F.;Caracas I.;Carceller J. M.;Caruso R.;Castellina A.;Catalani F.;Cataldi G.;Cazon L.;Cerda M.;Chinellato J. A.;Choi K.;Chudoba J.;Chytka L.;Clay R. W.;Cobos Cerutti A. C.;Colalillo R.;Coleman A.;Coluccia M. R.;Conceicao R.;Condorelli A.;Consolati G.;Contreras F.;Convenga F.;Correia dos Santos D.;Covault C. E.;Dasso S.;Daumiller K.;Dawson B. R.;Day J. A.;de Almeida R. M.;de Jesus J.;de Jong S. J.;De Mauro G.;de Mello Neto J. R. T.;De Mitri I.;de Oliveira J.;de Oliveira Franco D.;de Palma F.;de Souza V.;De Vito E.;del Rio M.;Deligny O.;Di Matteo A.;Dobrigkeit C.;D'Olivo J. C.;dos Anjos R. C.;Dova M. T.;Ebr J.;Engel R.;Epicoco I.;Erdmann M.;Escobar C. O.;Etchegoyen A.;Falcke H.;Farmer J.;Farrar G.;Fauth A. C.;Fazzini N.;Feldbusch F.;Fenu F.;Fick B.;Figueira J. M.;Filipcic A.;Fodran T.;Freire M. M.;Fujii T.;Fuster A.;Galea C.;Galelli C.;Garcia B.;Garcia Vegas A. L.;Gemmeke H.;Gesualdi F.;Gherghel-Lascu A.;Ghia P. L.;Giaccari U.;Giammarchi M.;Giller M.;Glombitza J.;Gobbi F.;Gollan F.;Golup G.;Gomez Berisso M.;Gomez Vitale P. F.;Gongora J. P.;Gonzalez J. M.;Gonzalez N.;Goos I.;Gora D.;Gorgi A.;Gottowik M.;Grubb T. D.;Guarino F.;Guedes G. P.;Guido E.;Hahn S.;Hamal P.;Hampel M. R.;Hansen P.;Harari D.;Harvey V. M.;Haungs A.;Hebbeker T.;Heck D.;Hill G. C.;Hojvat C.;Horandel J. R.;Horvath P.;Hrabovsky M.;Huege T.;Hulsman J.;Insolia A.;Isar P. G.;Janecek P.;Johnsen J. A.;Jurysek J.;Kaapa A.;Kampert K. H.;Keilhauer B.;Kemp J.;Klages H. O.;Kleifges M.;Kleinfeller J.;Kopke M.;Kunka N.;Lago B. L.;Lang R. G.;Langner N.;Leigui de Oliveira M. A.;Lenok V.;Letessier-Selvon A.;Lhenry-Yvon I.;Lo Presti D.;Lopes L.;Lopez R.;Lu L.;Luce Q.;Lucero A.;Lundquist J. P.;Machado Payeras A.;Mancarella G.;Mandat D.;Manning B. C.;Manshanden J.;Mantsch P.;Marafico S.;Mariazzi A. G.;Maris I. C.;Marsella G.;Martello D.;Martinez H.;Martinez Bravo O.;Mastrodicasa M.;Mathes H. J.;Matthews J.;Matthiae G.;Mayotte E.;Mazur P. O.;Medina-Tanco G.;Melo D.;Menshikov A.;Merenda K. -D.;Michal S.;Micheletti M. I.;Miramonti L.;Mollerach S.;Montanet F.;Morello C.;Mostafa M.;Muller A. L.;Muller M. A.;Mulrey K.;Mussa R.;Muzio M.;Namasaka W. M.;Nasr-Esfahani A.;Nellen L.;Niculescu-Oglinzanu M.;Niechciol M.;Nitz D.;Nosek D.;Novotny V.;Nozka L.;Nucita A.;Nunez L. A.;Palatka M.;Pallotta J.;Papenbreer P.;Parente G.;Parra A.;Pech M.;Pedreira F.;Pekala J.;Pelayo R.;Pena-Rodriguez J.;Pereira Martins E. E.;Perez Armand J.;Perez Bertolli C.;Perlin M.;Perrone L.;Petrera S.;Pierog T.;Pimenta M.;Pirronello V.;Platino M.;Pont B.;Pothast M.;Privitera P.;Prouza M.;Puyleart A.;Querchfeld S.;Rautenberg J.;Ravignani D.;Reininghaus M.;Ridky J.;Riehn F.;Risse M.;Rizi V.;Rodrigues de Carvalho W.;Rodriguez Rojo J.;Roncoroni M. J.;Roth M.;Roulet E.;Rovero A. C.;Ruehl P.;Saffi S. J.;Saftoiu A.;Salamida F.;Salazar H.;Salina G.;Sanabria Gomez J. D.;Sanchez F.;Santos E. M.;Santos E.;Sarazin F.;Sarmento R.;Sarmiento-Cano C.;Sato R.;Savina P.;Schafer C. M.;Scherini V.;Schieler H.;Schimassek M.;Schimp M.;Schluter F.;Schmidt D.;Scholten O.;Schovanek P.;Schroder F. G.;Schroder S.;Schulte J.;Sciutto S. J.;Scornavacche M.;Segreto A.;Sehgal S.;Shellard R. C.;Sigl G.;Silli G.;Sima O.;Smida R.;Sommers P.;Soriano J. F.;Souchard J.;Squartini R.;Stadelmaier M.;Stanca D.;Stanic S.;Stasielak J.;Stassi P.;Streich A.;Suarez-Duran M.;Sudholz T.;Suomijarvi T.;Supanitsky A. D.;Supik J.;Szadkowski Z.;Taboada A.;Tapia A.;Taricco C.;Timmermans C.;Tkachenko O.;Tobiska P.;Todero Peixoto C. J.;Tome B.;Travaini A.;Travnicek P.;Trimarelli C.;Trini M.;Tueros M.;Ulrich R.;Unger M.;Vaclavek L.;Vacula M.;Valdes Galicia J. F.;Valore L.;Varela E.;Varma V. K. C.;Vasquez-Ramirez A.;Veberic D.;Ventura C.;Vergara Quispe I. D.;Verzi V.;Vicha J.;Vink J.;Vorobiov S.;Wahlberg H.;Watanabe C.;Watson A. A.;Weber M.;Weindl A.;Wiencke L.;Wilczynski H.;Winchen T.;Wirtz M.;Wittkowski D.;Wundheiler B.;Yushkov A.;Zapparrata O.;Zas E.;Zavrtanik D.;Zavrtanik M.;Zehrer L.;Zepeda A.
2021-01-01
Abstract
To obtain direct measurements of the muon content of extensive air showers with energy above 101 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m close to the intersection of the shower axis with the ground to much less than one per m when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1803339
Citazioni
ND
9
12
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione.
La simulazione si basa sui dati IRIS e presenta gli indicatori calcolati alla data indicata sul report. Si ricorda che in sede di domanda ASN presso il MIUR gli indicatori saranno invece calcolati a partire dal 1° gennaio rispettivamente del quinto/decimo/quindicesimo anno precedente la scadenza del quadrimestre di presentazione della domanda (art 2 del DM 598/2018).
In questa simulazione pertanto il valore degli indicatori potrà differire da quello conteggiato all’atto della domanda ASN effettuata presso il MIUR a seguito di:
Correzioni imputabili a eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori.
Presenza di eventuali errori di catalogazione e/o dati mancanti in IRIS
Variabilità nel tempo dei valori citazionali (per i settori bibliometrici)
Variabilità della finestra temporale considerata in funzione della sessione di domanda ASN a cui si partecipa.
La presente simulazione è stata realizzata sulla base delle regole riportate nel DM 598/2018 e dell'allegata Tabella A e delle specifiche definite all'interno del Focus Group Cineca relativo al modulo IRIS ER. Il Cineca non si assume alcuna responsabilità in merito all'uso che il diretto interessato o terzi faranno della simulazione.