In this study are presented three cases of spinal cord ischemia (SCI) involving the cervical-dorsal level and leading to quadriplegia and quadriparesis, following thoracoabdominal aortic aneurysm (TAAA) endovascular repair. A 79-year-old woman with an extent III TAAA was scheduled for a multi-step fenestrated/branched endovascular aortic repair. Immediately after the first step, consisting of standard proximal thoracic stent-graft implantation, she developed quadriplegia that did not resolve despite all therapeutic actions, and died therefore on postoperative day 32. A 72-year old male with an extent IV TAAA underwent endovascular repair, using a customized fenestrated aortic stent-graft. Five hours after the procedure, he developed an asymmetric quadriparesis, that progressively resolved after spinal fluid drainage and arterial pressure increase, even if signs of SCI were documented at magnetic resonance imaging (MRI). A 79-year old man, referred for a type II TAAA with rapid enlargement, underwent a one-stage endovascular repair, using a customized branched aortic stent-graft. As soon as the procedure was completed, the patient presented inferior limbs paralysis and upper limbs paresis. Although no signs of SCI were documented at MRI, the patient did not recover and died therefore three months after the procedure. Although rare, cervical-dorsal SCI may develop during TAAA endovascular aortic repair. This possibly catastrophic event should be considered in the decisional process of TAAA repair and considered to allow prompt recognition and treatment.

Quadriplegia and quadriparesis after endovascular aortic procedures: A catastrophic and under-reported complication?

Verzini F.;
2020-01-01

Abstract

In this study are presented three cases of spinal cord ischemia (SCI) involving the cervical-dorsal level and leading to quadriplegia and quadriparesis, following thoracoabdominal aortic aneurysm (TAAA) endovascular repair. A 79-year-old woman with an extent III TAAA was scheduled for a multi-step fenestrated/branched endovascular aortic repair. Immediately after the first step, consisting of standard proximal thoracic stent-graft implantation, she developed quadriplegia that did not resolve despite all therapeutic actions, and died therefore on postoperative day 32. A 72-year old male with an extent IV TAAA underwent endovascular repair, using a customized fenestrated aortic stent-graft. Five hours after the procedure, he developed an asymmetric quadriparesis, that progressively resolved after spinal fluid drainage and arterial pressure increase, even if signs of SCI were documented at magnetic resonance imaging (MRI). A 79-year old man, referred for a type II TAAA with rapid enlargement, underwent a one-stage endovascular repair, using a customized branched aortic stent-graft. As soon as the procedure was completed, the patient presented inferior limbs paralysis and upper limbs paresis. Although no signs of SCI were documented at MRI, the patient did not recover and died therefore three months after the procedure. Although rare, cervical-dorsal SCI may develop during TAAA endovascular aortic repair. This possibly catastrophic event should be considered in the decisional process of TAAA repair and considered to allow prompt recognition and treatment.
2020
61
5
632
638
Angioplasty; Aortic aneurysm; Quadriplegia; Spinal cord ischemia; Aged; Aortic Aneurysm, Thoracic; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Fatal Outcome; Female; Humans; Male; Multiple Organ Failure; Quadriplegia; Spinal Cord Ischemia; Time Factors; Treatment Outcome
Kahlberg A.; Tenorio E.R.; Grandi A.; Oderich G.S.; Verzini F.; Cieri E.; Baccani L.; Melissano G.; Chiesa R.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1865448
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact