Despite the improvement in diagnostic and therapeutic strategies, the treatment of thoracoabdominal aneurysms is still burdened with a high incidence of peri/postoperative morbidity and mortality. The multilayer flow modulator is a new and promising technique for the treatment of such disease; however, some limits are still evident. We report the case of a 76-year-old woman affected by a symptomatic thoracoabdominal aneurysm treated with multiple Cardiatis multilayer flow modulators complicated by aortic arch rupture on the fifth postoperative day, with subsequent patient death.
Aortic arch rupture after multiple multilayer stent treatment of a thoracoabdominal aneurysm
Gibello, Lorenzo;Viazzo, Andrea;
2014-01-01
Abstract
Despite the improvement in diagnostic and therapeutic strategies, the treatment of thoracoabdominal aneurysms is still burdened with a high incidence of peri/postoperative morbidity and mortality. The multilayer flow modulator is a new and promising technique for the treatment of such disease; however, some limits are still evident. We report the case of a 76-year-old woman affected by a symptomatic thoracoabdominal aneurysm treated with multiple Cardiatis multilayer flow modulators complicated by aortic arch rupture on the fifth postoperative day, with subsequent patient death.File in questo prodotto: