X-ray Computed Tomography (CT) is a widely used diagnostic technique in the field of Cultural Heritage and beyond, above all thanks to its non-invasiveness. The high penetrating power of X-rays allows us to investigate the internal structure of the analysed objects, thus obtaining valuable information related to the history of artistic and archaeological finds. In particular, CT provides useful data on the entire volume of the objects, to finally obtain a 3D model of the studied artworks. In this field, the goal of the "neu_ART" project, a collaboration among different institutions in Torino funded by Regione Piemonte in 2010, was to develop radio-tomographic set-ups for X-ray imaging analysis dedicated to Cultural Heritage studies. In this paper, a computed tomography investigation on an ancient ceramic rattle from the Museum of Anthropology and Ethnography of the University of Torino is presented. This is the first analysis carried out at the Physics Department of University of Torino, using the imaging set-up based on a TDI linear detector moved by a high precision mechanical system. Thanks to this study, much information on the technique of execution and the state of conservation was obtained.
The study of ancient archaeological finds through X-ray tomography: The case of the " Tintinnabulum" from the Museum of Anthropology and Ethnography of Torino
Vigorelli L.;Re A.
;Guidorzi L.;Mila G.;Sacchi R.;Mangiapane G.;Boano R.;Lo Giudice A.Last
2022-01-01
Abstract
X-ray Computed Tomography (CT) is a widely used diagnostic technique in the field of Cultural Heritage and beyond, above all thanks to its non-invasiveness. The high penetrating power of X-rays allows us to investigate the internal structure of the analysed objects, thus obtaining valuable information related to the history of artistic and archaeological finds. In particular, CT provides useful data on the entire volume of the objects, to finally obtain a 3D model of the studied artworks. In this field, the goal of the "neu_ART" project, a collaboration among different institutions in Torino funded by Regione Piemonte in 2010, was to develop radio-tomographic set-ups for X-ray imaging analysis dedicated to Cultural Heritage studies. In this paper, a computed tomography investigation on an ancient ceramic rattle from the Museum of Anthropology and Ethnography of the University of Torino is presented. This is the first analysis carried out at the Physics Department of University of Torino, using the imaging set-up based on a TDI linear detector moved by a high precision mechanical system. Thanks to this study, much information on the technique of execution and the state of conservation was obtained.File | Dimensione | Formato | |
---|---|---|---|
2022 Vigorelli et al - JoPCS 2204(1)[012034].pdf
Accesso aperto
Descrizione: PDF editoriale
Tipo di file:
PDF EDITORIALE
Dimensione
1.05 MB
Formato
Adobe PDF
|
1.05 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.