A proton counter prototype based on Low Gain Avalanche Detector (LGAD) technology is being developed for the online monitoring of the fluence rate of therapeutic proton beams. The laboratory characterization of thin (45 mu m and 60 mu m) LGAD sensors segmented in 146 strips with an unprecedented large area of 2.6 x 2.6 cm(2), covering the entire beam cross-section, is presented and discussed. The production includes 14 wafers with different characteristics, designed and produced at Fondazione Bruno Kessler (FBK) of Trento in 2020. The laboratory characterization was carried out at FBK, right after production, and at the University of Torino, after cutting the sensors, using a probe station with a power analyzer for the static DC electrical tests. The tests proved that the production was of very high quality. From 16 sensors randomly selected from different wafers, we observed consistency between the measurements performed at FBK and at the University of Torino, indicating that the cut did not degrade the performance. The sensors were also exposed to the clinical proton beam of the National Center for Oncological Hadrontherapy (CNAO, Pavia, Italy). The results show that LGADs allow achieving, in a very thin active thickness, a good separation between the proton signal, a peak of a very short duration, and the noise. This, combined with the large active area, will allow counting protons delivered with high efficiency at the high rates of a clinical beam.

Characterization of large LGAD sensors for proton counting in particle therapy

Vignati, A;Milian, FM;Menzio, L;Abujami, M;Galeone, C;Borghi, G;Cirio, R;Monaco, V;Sacchi, R
2022-01-01

Abstract

A proton counter prototype based on Low Gain Avalanche Detector (LGAD) technology is being developed for the online monitoring of the fluence rate of therapeutic proton beams. The laboratory characterization of thin (45 mu m and 60 mu m) LGAD sensors segmented in 146 strips with an unprecedented large area of 2.6 x 2.6 cm(2), covering the entire beam cross-section, is presented and discussed. The production includes 14 wafers with different characteristics, designed and produced at Fondazione Bruno Kessler (FBK) of Trento in 2020. The laboratory characterization was carried out at FBK, right after production, and at the University of Torino, after cutting the sensors, using a probe station with a power analyzer for the static DC electrical tests. The tests proved that the production was of very high quality. From 16 sensors randomly selected from different wafers, we observed consistency between the measurements performed at FBK and at the University of Torino, indicating that the cut did not degrade the performance. The sensors were also exposed to the clinical proton beam of the National Center for Oncological Hadrontherapy (CNAO, Pavia, Italy). The results show that LGADs allow achieving, in a very thin active thickness, a good separation between the proton signal, a peak of a very short duration, and the noise. This, combined with the large active area, will allow counting protons delivered with high efficiency at the high rates of a clinical beam.
2022
Inglese
contributo
1 - Conferenza
PSD - Position Sensitive Detector
England (and ONLINE)
12 - 17 sept 2021
Internazionale
Esperti anonimi
17
9
1
5
5
Instrumentation for hadron therapy; Si microstrip and pad detectors; Solid state detectors; Timing detectors
BRASILE
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
04-CONTRIBUTO IN ATTI DI CONVEGNO::04B-Conference paper in rivista
info:eu-repo/semantics/conferenceObject
16
open
Villarreal, OAM; Peroglio, G; Vignati, A; Giordanengo, S; Milian, FM; Ferrero, M; Menzio, L; Abujami, M; Galeone, C; Ali, OH; Vignali, MC; Borghi, G; ...espandi
273
File in questo prodotto:
File Dimensione Formato  
jinst-MartiVillarreal.pdf

Accesso aperto

Tipo di file: PREPRINT (PRIMA BOZZA)
Dimensione 294.26 kB
Formato Adobe PDF
294.26 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1890943
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact