BACKGROUND: The introduction of intraoperative computed tomography (iCT) could improve the surgical results of C1-C2 stabilization by Goel-Harms, especially in patients with complex deformities. This study aims to investigate the impact of iCT on the accuracy of C1-C2 screw positioning and to develop a score based on multiparametric analysis of imaging data (Cervical Screw Placement Accuracy score [CSPAs]).METHODS: Twenty-one patients were retrospectively evaluated. The data obtained with the use of an iCT were compared with the incidence of cases of malpositioning in the literature. Multiparametric imaging criteria were developed: the 82 screw positions were evaluated using the CSPA criteria and 2 additional variables. The CSPAs was obtained from the aggregation of the CSPAs criteria: optimal (CSPAs >= 8), suboptimal (CSPAs = 6-7), malpositioned (CSPAs <= 5).RESULTS: The average incidence of malpositioning in C1-C2 arthrodesis decreased from 13% without iCT to 1.2% with the aid of iCT, considering a monoparametric value. The CSPAs analysis shows a greater discretion and higher number of well-defined categories of the accuracy of C1-C2 screw position: optimal, 80.3%; suboptimal, 17.1%; and malposition, 2.6%. A correlation was observed between the accuracy of the positioning of both right and left screws in C2. Furthermore, the anatomic site of C2 screws was found to be a predictor of cortical invasion.CONCLUSIONS: The results suggest that the introduction of the iCT is associated with a consistent improvement of the accuracy in the positioning of the screws. A multiparametric score (CSPAs) could improve the assessment of screw placement.

Intraoperative Computed Tomography for C1-C2 Stabilization by Goel-Harms: Analysis of Clinical Efficacy and a Novel Classification of Screw Placement Accuracy

Sancipriano, Vittorio;Penner, Federica;Cofano, Fabio;Ajello, Marco;Marengo, Nicola;Petrone, Salvatore;Zenga, Francesco;Cossandi, Christian;Garbossa, Diego
2022-01-01

Abstract

BACKGROUND: The introduction of intraoperative computed tomography (iCT) could improve the surgical results of C1-C2 stabilization by Goel-Harms, especially in patients with complex deformities. This study aims to investigate the impact of iCT on the accuracy of C1-C2 screw positioning and to develop a score based on multiparametric analysis of imaging data (Cervical Screw Placement Accuracy score [CSPAs]).METHODS: Twenty-one patients were retrospectively evaluated. The data obtained with the use of an iCT were compared with the incidence of cases of malpositioning in the literature. Multiparametric imaging criteria were developed: the 82 screw positions were evaluated using the CSPA criteria and 2 additional variables. The CSPAs was obtained from the aggregation of the CSPAs criteria: optimal (CSPAs >= 8), suboptimal (CSPAs = 6-7), malpositioned (CSPAs <= 5).RESULTS: The average incidence of malpositioning in C1-C2 arthrodesis decreased from 13% without iCT to 1.2% with the aid of iCT, considering a monoparametric value. The CSPAs analysis shows a greater discretion and higher number of well-defined categories of the accuracy of C1-C2 screw position: optimal, 80.3%; suboptimal, 17.1%; and malposition, 2.6%. A correlation was observed between the accuracy of the positioning of both right and left screws in C2. Furthermore, the anatomic site of C2 screws was found to be a predictor of cortical invasion.CONCLUSIONS: The results suggest that the introduction of the iCT is associated with a consistent improvement of the accuracy in the positioning of the screws. A multiparametric score (CSPAs) could improve the assessment of screw placement.
2022
158
19
37
C1-C2 stabilization; Classification; Goel-Harms technique; Intraoperative CT scan; Screw accuracy
Sancipriano, Vittorio; Penner, Federica; Cofano, Fabio; Ajello, Marco; Marengo, Nicola; Petrone, Salvatore; Zenga, Francesco; Crobeddu, Manuela; Bianco, Andrea; Cossandi, Christian; Garbossa, Diego
File in questo prodotto:
File Dimensione Formato  
C1-C2 stabilization_classification accuracy.pdf

Accesso riservato

Dimensione 4.34 MB
Formato Adobe PDF
4.34 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1901942
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact