We describe the case of a patient who had been on hemodialysis for 8 years using a native arteriovenous fistula cannulated through the Venous Window Needle Guide (TM) device (VWING). The overall outcome was excellent and complication-free with intact state of the underlying vessel and a high degree of patient satisfaction. The patient was able to carry out self-cannulation without any difficulty almost from the very beginning. The current unavailability of VWING is a missed opportunity in the field of vascular access.
Successful 8-year use of Venous Window Needle Guide for deep arteriovenous fistula cannulation
Roccatello, Dario
2022-01-01
Abstract
We describe the case of a patient who had been on hemodialysis for 8 years using a native arteriovenous fistula cannulated through the Venous Window Needle Guide (TM) device (VWING). The overall outcome was excellent and complication-free with intact state of the underlying vessel and a high degree of patient satisfaction. The patient was able to carry out self-cannulation without any difficulty almost from the very beginning. The current unavailability of VWING is a missed opportunity in the field of vascular access.File in questo prodotto: