A new procedure for the determination of Al, Ba, Ca, Fe, K, Mg, Na and Sr in snow samples by inductively coupled plasma optical emission spectrometry (ICP-OES) has been developed. The analytes were 100-fold preconcentrated by sample volume reduction and quantified by ICP-OES using the heated torch-integrated sample introduction system (hTISIS). After multivariate optimization of the hTISIS/ICP-OES operating parameters for maximum sensitivity and plasma robustness, fit-for-purpose performances were achieved, requiring only 20 mL of sample (as water equivalent). The analytical recovery was quantitative (except for Ba at low concentration, ≈80%) and the precision of the procedure was better than 5%. The limits of detection (Al: 0.10 ng g−1; Ba: 0.013 ng g−1; Ca: 0.52 ng g−1; Fe: 0.13 ng g−1; K: 0.38 ng g−1; Mg: 0.04 ng g−1; Na: 0.39 ng g−1; Sr: 0.003 ng g−1) were suitable for the analysis of Antarctic snow, with some limitation for Ba. The accuracy of the method was assessed by the analysis of the certified reference water NIST SRM 1640a. The application of the analytical method to sixty snow samples collected at Dome C, on the East Antarctic Plateau, provided self-consistent results, in good agreement with literature data.

Determination of major elements in Antarctic snow by inductively coupled plasma optical emission spectrometry using a total-consumption sample introduction system

Bertinetti S.;
2021-01-01

Abstract

A new procedure for the determination of Al, Ba, Ca, Fe, K, Mg, Na and Sr in snow samples by inductively coupled plasma optical emission spectrometry (ICP-OES) has been developed. The analytes were 100-fold preconcentrated by sample volume reduction and quantified by ICP-OES using the heated torch-integrated sample introduction system (hTISIS). After multivariate optimization of the hTISIS/ICP-OES operating parameters for maximum sensitivity and plasma robustness, fit-for-purpose performances were achieved, requiring only 20 mL of sample (as water equivalent). The analytical recovery was quantitative (except for Ba at low concentration, ≈80%) and the precision of the procedure was better than 5%. The limits of detection (Al: 0.10 ng g−1; Ba: 0.013 ng g−1; Ca: 0.52 ng g−1; Fe: 0.13 ng g−1; K: 0.38 ng g−1; Mg: 0.04 ng g−1; Na: 0.39 ng g−1; Sr: 0.003 ng g−1) were suitable for the analysis of Antarctic snow, with some limitation for Ba. The accuracy of the method was assessed by the analysis of the certified reference water NIST SRM 1640a. The application of the analytical method to sixty snow samples collected at Dome C, on the East Antarctic Plateau, provided self-consistent results, in good agreement with literature data.
2021
181
1
6
Antarctica; Atomic emission spectrometry; Sample introduction; Snow; Trace metals
Bertinetti S.; Ardini F.; Caiazzo L.; Grotti M.
File in questo prodotto:
File Dimensione Formato  
Bertinetti_SAB_2021.pdf

Accesso aperto

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 373.16 kB
Formato Adobe PDF
373.16 kB Adobe PDF Visualizza/Apri
Bertinetti_SAB_2021_supplementary2.docx

Accesso aperto

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 50.95 kB
Formato Microsoft Word XML
50.95 kB Microsoft Word XML Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1950386
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact