Background: Glyphosate has been extensively used as herbicide since the early 1970s. The daily exposure limit is set at 0.3 mg/kg bw/d in Europe and 1.75 mg/kg bw/d in the USA. Among its derivatives, aminomethylphosphonic acid is the most stable and abundant. Understanding their biological effects then requires reliable methods for quantification in biological samples. Methods: We developed and validated a fast, low-cost, and reliable chromatographic method for determining glyphosate and aminomethylphosphonic acid concentrations. The validation included following parameters: specificity, selectivity, matrix effect, accuracy, precision, calibration performance, limit of quantification, recovery, and stability. Sample extraction employed an anion exchange resin with elution using hydrochloric acid 50.0 mmol/L. For HPLC analysis, analytes were derivatized, separated on a C18 column with a mobile phase of phosphate buffer (0.20 mol/L, pH 3.0) and acetonitrile (85:15), and detected at 240 nm. Results: The method demonstrated high reliability and reproducibility across various matrices. Its performance met all validation criteria, confirming its suitability for quantifying glyphosate and aminomethylphosphonic acid in different biological and experimental setups. Conclusions: This method can offer a practical resource for applications in experimental research, medical diagnostics, quality control, and food safety.

New Standardized Procedure to Extract Glyphosate and Aminomethylphosphonic Acid from Different Matrices: A Kit for HPLC-UV Detection

Chiara, Francesco
First
;
Allegra, Sarah
;
Arrigo, Elisa;Di Grazia, Daniela;Shelton Agar, Francesco Maximillian Anthony;Abalai, Raluca Elena;Gilardi, Sara;De Francia, Silvia;Mancardi, Daniele
Last
2025-01-01

Abstract

Background: Glyphosate has been extensively used as herbicide since the early 1970s. The daily exposure limit is set at 0.3 mg/kg bw/d in Europe and 1.75 mg/kg bw/d in the USA. Among its derivatives, aminomethylphosphonic acid is the most stable and abundant. Understanding their biological effects then requires reliable methods for quantification in biological samples. Methods: We developed and validated a fast, low-cost, and reliable chromatographic method for determining glyphosate and aminomethylphosphonic acid concentrations. The validation included following parameters: specificity, selectivity, matrix effect, accuracy, precision, calibration performance, limit of quantification, recovery, and stability. Sample extraction employed an anion exchange resin with elution using hydrochloric acid 50.0 mmol/L. For HPLC analysis, analytes were derivatized, separated on a C18 column with a mobile phase of phosphate buffer (0.20 mol/L, pH 3.0) and acetonitrile (85:15), and detected at 240 nm. Results: The method demonstrated high reliability and reproducibility across various matrices. Its performance met all validation criteria, confirming its suitability for quantifying glyphosate and aminomethylphosphonic acid in different biological and experimental setups. Conclusions: This method can offer a practical resource for applications in experimental research, medical diagnostics, quality control, and food safety.
2025
15
1
1
14
AMPA; HPLC-UV; biological matrix; glyphosate; liquid chromatography
Chiara, Francesco; Allegra, Sarah; Arrigo, Elisa; Di Grazia, Daniela; Shelton Agar, Francesco Maximillian Anthony; Abalai, Raluca Elena; Gilardi, Sara...espandi
File in questo prodotto:
File Dimensione Formato  
jox-15-00023.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2061695
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact