The purpose of this study was to develop an automatic method for the segmentation of muscle cross-sectional area on transverse B-mode ultrasound images of gastrocnemius medialis using a convolutional neural network(CNN). In the provided dataset images with both normal and increased echogenicity are present. The manually annotated dataset consisted of 591 images, from 200 subjects, 400 relative to subjects with normal echogenicity and 191 to subjects with augmented echogenicity. From the DICOM files, the image has been extracted and processed using the CNN, then the output has been post-processed to obtain a finer segmentation. Final results have been compared to the manual segmentations. Precision and Recall scores as mean ± standard deviation for training, validation, and test sets are 0.96 ± 0.05, 0.90 ± 0.18, 0.89 ± 0.15 and 0.97 ±0.03, 0.89± 0.17, 0.90 ± 0.14 respectively. The CNN approach has also been compared to another automatic algorithm, showing better performances. The proposed automatic method provides an accurate estimation of muscle cross-sectional area in muscles with different echogenicity levels.

Automatic segmentation of ultrasound images of gastrocnemius medialis with different echogenicity levels using convolutional neural networks

Marzola F.
First
;
Salvi M.;De Santi B.;Meiburger K. M.
2020-01-01

Abstract

The purpose of this study was to develop an automatic method for the segmentation of muscle cross-sectional area on transverse B-mode ultrasound images of gastrocnemius medialis using a convolutional neural network(CNN). In the provided dataset images with both normal and increased echogenicity are present. The manually annotated dataset consisted of 591 images, from 200 subjects, 400 relative to subjects with normal echogenicity and 191 to subjects with augmented echogenicity. From the DICOM files, the image has been extracted and processed using the CNN, then the output has been post-processed to obtain a finer segmentation. Final results have been compared to the manual segmentations. Precision and Recall scores as mean ± standard deviation for training, validation, and test sets are 0.96 ± 0.05, 0.90 ± 0.18, 0.89 ± 0.15 and 0.97 ±0.03, 0.89± 0.17, 0.90 ± 0.14 respectively. The CNN approach has also been compared to another automatic algorithm, showing better performances. The proposed automatic method provides an accurate estimation of muscle cross-sectional area in muscles with different echogenicity levels.
2020
42nd Annual International Conferences of the IEEE Engineering in Medicine and Biology Society, EMBC 2020
Montreal, QC, Canada
20-24 July 2020
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
Institute of Electrical and Electronics Engineers Inc.
2020
2113
2116
978-1-7281-1990-8
https://pubmed.ncbi.nlm.nih.gov/33018423/
Algorithms; Humans; Muscle; Skeletal; Ultrasonography; Image Processing; Computer-Assisted; Neural Networks; Computer
Marzola F.; Alfen N. V.; Salvi M.; De Santi B.; Doorduin J.; Meiburger K. M.
File in questo prodotto:
File Dimensione Formato  
EMBC_final.pdf

Accesso riservato

Dimensione 1.62 MB
Formato Adobe PDF
1.62 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2104080
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact