Numerous formulas have been developed to estimate renal function from biochemical, demographic and anthropometric data. Here we compared renal function derived from 12 published prediction equations with glomerular filtration rate (GFR) measurement by plasma iohexol clearance as reference method in a group of 81 renal transplant recipients enrolled in the Mycophenolate Mofetil Steroid Sparing (MY.S.S.) trial. Iohexol clearances and prediction equations were carried out in all patients at months 6, 9 and 21 after surgery. All equations showed a tendency toward GFR over-estimation: Walser and MDRD equations gave the best performance, however not more than 45% of estimated values were within +/-10% error. These formulas showed also the lowest bias and the highest precision: 0.5 and 9.2 mL/min/1.73 m2 (Walser), 2.7 and 10.4 mL/min/1.73 m2 (MDRD) in predicting GFR. A significantly higher rate of GFR decline ranging from -5.0 mL/min/1.73 m2/year (Walser) to -7.4 mL/min/1.73 m2/year (Davis-Chandler) was estimated by all the equations as compared with iohexol clearance (-3.0 mL/min/1.73 m2/year). The 12 prediction equations do not allow a rigorous assessment of renal function in kidney transplant recipients. In clinical trials of kidney transplantation, graft function should be preferably monitored using a reference method of GFR measurement, such as iohexol plasma clearance.

Performance of different prediction equations for estimating renal function in kidney transplantation

SEGOLONI, Giuseppe;
2004-01-01

Abstract

Numerous formulas have been developed to estimate renal function from biochemical, demographic and anthropometric data. Here we compared renal function derived from 12 published prediction equations with glomerular filtration rate (GFR) measurement by plasma iohexol clearance as reference method in a group of 81 renal transplant recipients enrolled in the Mycophenolate Mofetil Steroid Sparing (MY.S.S.) trial. Iohexol clearances and prediction equations were carried out in all patients at months 6, 9 and 21 after surgery. All equations showed a tendency toward GFR over-estimation: Walser and MDRD equations gave the best performance, however not more than 45% of estimated values were within +/-10% error. These formulas showed also the lowest bias and the highest precision: 0.5 and 9.2 mL/min/1.73 m2 (Walser), 2.7 and 10.4 mL/min/1.73 m2 (MDRD) in predicting GFR. A significantly higher rate of GFR decline ranging from -5.0 mL/min/1.73 m2/year (Walser) to -7.4 mL/min/1.73 m2/year (Davis-Chandler) was estimated by all the equations as compared with iohexol clearance (-3.0 mL/min/1.73 m2/year). The 12 prediction equations do not allow a rigorous assessment of renal function in kidney transplant recipients. In clinical trials of kidney transplantation, graft function should be preferably monitored using a reference method of GFR measurement, such as iohexol plasma clearance.
2004
Inglese
Sì, ma tipo non specificato
4
1826
1835
262
17
GASPARI F; FERRARI S; STUCCHI N; CENTEMERI E; CARRARA F; PELLEGRINO M; GHERARDI G; GOTTI E; SEGOLONI G; SALVADORI M; RIGOTTI P; VALENTE U; DONATI D; S...espandi
info:eu-repo/semantics/article
none
03-CONTRIBUTO IN RIVISTA::03A-Articolo su Rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/39447
Citazioni
  • ???jsp.display-item.citation.pmc??? 31
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact