A quantitative lateral flow immunoassay for measuring fumonisins in maize was developed. Strip preparation and assay parameters were optimized to obtain a dipstick usable outside the laboratory with different samples, and which shows performance comparable with that of other screening methods, as confirmed by the intra- and the interday precision of data (RSD5–16%). Quantification was obtained by an external calibration curve, which can be stored and used for measurements made with strips of the same batch in different days and at varying temperatures (22–37 ◦C). Limit of detection (120 mug/l) and dynamic range (200–5000 mug/l) allow the direct assessment of fumonisin contamination at all levels of regulatory relevance. Twentyseven maize samples were analyzed after a simple sample preparation which avoids the use of organic solvent. Linear correlation was observed (y=1.071x−0.2, r2 = 0.990) when data was compared with that obtained through a reference LC–MS/MS method, across a wide range of fumonisin contamination

Development and application of a quantitative lateral flow immunoassay for fumonisins in maize

ANFOSSI, Laura;BAGGIANI, Claudio;GIOVANNOLI, Cristina;GIRAUDI, Gianfranco
2010-01-01

Abstract

A quantitative lateral flow immunoassay for measuring fumonisins in maize was developed. Strip preparation and assay parameters were optimized to obtain a dipstick usable outside the laboratory with different samples, and which shows performance comparable with that of other screening methods, as confirmed by the intra- and the interday precision of data (RSD5–16%). Quantification was obtained by an external calibration curve, which can be stored and used for measurements made with strips of the same batch in different days and at varying temperatures (22–37 ◦C). Limit of detection (120 mug/l) and dynamic range (200–5000 mug/l) allow the direct assessment of fumonisin contamination at all levels of regulatory relevance. Twentyseven maize samples were analyzed after a simple sample preparation which avoids the use of organic solvent. Linear correlation was observed (y=1.071x−0.2, r2 = 0.990) when data was compared with that obtained through a reference LC–MS/MS method, across a wide range of fumonisin contamination
2010
682
104
109
L.Anfossi; M.Calderara; C.Baggiani; C.Giovannoli; E.Arletti; G.Giraudi
File in questo prodotto:
File Dimensione Formato  
aca10_682_104.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 268.91 kB
Formato Adobe PDF
268.91 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
aca10_682_104_draft.pdf

Open Access dal 01/03/2014

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 332.36 kB
Formato Adobe PDF
332.36 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/78023
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 77
  • ???jsp.display-item.citation.isi??? 72
social impact