compact portable chemiluminescent biosensor for simple, rapid, and ultrasensitive on-site quantification of fumonisins (fumonisin B1 + fumonisin B2) in maize has been developed. The biosensor integrates a competitive lateral flow immunoassay based on enzyme-catalyzed chemiluminescence detection and a highly sensitive portable charge-coupled device (CCD) camera, employed in a contact imaging configuration. The use of chemiluminescence detection allowed accurate and objective analyte quantification, rather than qualitative or semi-quantitative information usually obtained employing conventional lateral flow immunoassays based on colloidal gold labeling. A limit of detection of 2.5 mug/L for fumonisins was achieved, with an analytical working range of 2.5–500 mug/L (corresponding to 25–5000 mug/kg in maize flour samples, according to the extraction procedure). Total assay time was 25 min, including sample preparation. A simple and convenient extraction procedure, performed by suspending the sample in a buffered solution and rapidly heating to eliminate endogenous peroxidase enzyme activity was employed for maize flour samples analysis, obtaining recoveries in the range 90–115%, when compared with LC–MS/MS analysis. The chemiluminescence immunochromatography-based biosensor is a rapid, low cost portable test suitable for point-of-use applications

Chemiluminescence-based biosensor for fumonisins quantitative detection in maize samples

ANFOSSI, Laura;GIRAUDI, Gianfranco;
2012-01-01

Abstract

compact portable chemiluminescent biosensor for simple, rapid, and ultrasensitive on-site quantification of fumonisins (fumonisin B1 + fumonisin B2) in maize has been developed. The biosensor integrates a competitive lateral flow immunoassay based on enzyme-catalyzed chemiluminescence detection and a highly sensitive portable charge-coupled device (CCD) camera, employed in a contact imaging configuration. The use of chemiluminescence detection allowed accurate and objective analyte quantification, rather than qualitative or semi-quantitative information usually obtained employing conventional lateral flow immunoassays based on colloidal gold labeling. A limit of detection of 2.5 mug/L for fumonisins was achieved, with an analytical working range of 2.5–500 mug/L (corresponding to 25–5000 mug/kg in maize flour samples, according to the extraction procedure). Total assay time was 25 min, including sample preparation. A simple and convenient extraction procedure, performed by suspending the sample in a buffered solution and rapidly heating to eliminate endogenous peroxidase enzyme activity was employed for maize flour samples analysis, obtaining recoveries in the range 90–115%, when compared with LC–MS/MS analysis. The chemiluminescence immunochromatography-based biosensor is a rapid, low cost portable test suitable for point-of-use applications
2012
32
283
287
M.Mirasoli; A.Buragina; L.S.Dolci; P.Simoni; L.Anfossi; G.Giraudi; A.Roda
File in questo prodotto:
File Dimensione Formato  
bb12_32_0283.pdf

Accesso riservato

Tipo di file: PDF EDITORIALE
Dimensione 381.62 kB
Formato Adobe PDF
381.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
bb12_32_0283_draft.pdf

Open Access dal 01/01/2017

Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 615.28 kB
Formato Adobe PDF
615.28 kB Adobe PDF Visualizza/Apri
bb12_32_0283_si.pdf

Accesso aperto

Descrizione: supporting informations
Tipo di file: MATERIALE NON BIBLIOGRAFICO
Dimensione 121.52 kB
Formato Adobe PDF
121.52 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/99099
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 68
social impact