OBJECTIVE: To compare patterns of acute and late radiological lung injury following either 3D conformal or image-guided volumetric modulated arc therapy stereotactic radiotherapy for Stage I non-small-cell lung cancer. METHODS: We included 148 patients from a prospective mono-institutional stereotactic body radiation therapy (SBRT) series (time interval 2004-2014), treated with prescription BED10 Gy (at 80%) in the range 100-120 Gy. The first 95 patients (2004-2010) were planned with 3D-CRT, with a stereotactic body frame. The second cohort (2010-2014) included 53 patients, planned with volumetric IMRT on a smaller planning target volume generated from a patient's specific internal target volume, with a frameless approach through cone-beam CT guidance. Acute and late radiological modifications were scored based on modified Kimura's and Koenig's classifications, respectively. RESULTS: Median follow-up time was 20.5 months. The incidence of acute radiological changes was superimposable between the groups: increased density was observed in 68.4 and 64.2% of patients for 3D-CRT and VMAT, respectively, and patchy ground glass opacity in 23.7 and 24.5%, respectively; diffuse ground glass opacity was 2.6 vs 9.4%, respectively, and patchy consolidation 2.6 vs 1.9%, respectively. Late changes occurred in approximately 60% of patients: modified conventional pattern was the most frequent modification (25 vs 32.6%, respectively); other patterns were less common (mass-like 19.6 vs 17.4%, and scar-like 13 vs 10.9%, respectively). CONCLUSION: Results of the present study indicate that the pattern of radiological lung changes following SBRT for peripheral early stage non-small-cell lung cancer is not influenced by the different techniques used for planning and delivery. Advances in knowledge: This comparative observational study shows that smaller margins, image guidance and most importantly dose distribution do not change the pattern of radiological injury after lung SBRT; the same scoring system can be used, and expected incidence is similar.
No differences in radiological changes after 3D conformal vs VMAT-based stereotactic radiotherapy for early stage non-small cell lung cancer
Badellino, Serena;Di Muzio, Jacopo;Guarneri, Alessia;Ragona, Riccardo;Trino, Elisabetta;Filippi, Andrea Riccardo;Fonio, Paolo;Ricardi, Umberto
Last
2017-01-01
Abstract
OBJECTIVE: To compare patterns of acute and late radiological lung injury following either 3D conformal or image-guided volumetric modulated arc therapy stereotactic radiotherapy for Stage I non-small-cell lung cancer. METHODS: We included 148 patients from a prospective mono-institutional stereotactic body radiation therapy (SBRT) series (time interval 2004-2014), treated with prescription BED10 Gy (at 80%) in the range 100-120 Gy. The first 95 patients (2004-2010) were planned with 3D-CRT, with a stereotactic body frame. The second cohort (2010-2014) included 53 patients, planned with volumetric IMRT on a smaller planning target volume generated from a patient's specific internal target volume, with a frameless approach through cone-beam CT guidance. Acute and late radiological modifications were scored based on modified Kimura's and Koenig's classifications, respectively. RESULTS: Median follow-up time was 20.5 months. The incidence of acute radiological changes was superimposable between the groups: increased density was observed in 68.4 and 64.2% of patients for 3D-CRT and VMAT, respectively, and patchy ground glass opacity in 23.7 and 24.5%, respectively; diffuse ground glass opacity was 2.6 vs 9.4%, respectively, and patchy consolidation 2.6 vs 1.9%, respectively. Late changes occurred in approximately 60% of patients: modified conventional pattern was the most frequent modification (25 vs 32.6%, respectively); other patterns were less common (mass-like 19.6 vs 17.4%, and scar-like 13 vs 10.9%, respectively). CONCLUSION: Results of the present study indicate that the pattern of radiological lung changes following SBRT for peripheral early stage non-small-cell lung cancer is not influenced by the different techniques used for planning and delivery. Advances in knowledge: This comparative observational study shows that smaller margins, image guidance and most importantly dose distribution do not change the pattern of radiological injury after lung SBRT; the same scoring system can be used, and expected incidence is similar.File | Dimensione | Formato | |
---|---|---|---|
No differences in radiological 2018.pdf
Accesso riservato
Tipo di file:
PDF EDITORIALE
Dimensione
647.13 kB
Formato
Adobe PDF
|
647.13 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
No differences in radiological 2018 POSTPRINT.pdf
Accesso aperto
Tipo di file:
POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione
181.81 kB
Formato
Adobe PDF
|
181.81 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.