The detection of nitazenes in biological fluids is increasingly needed as they are repeatedly reported in intoxication and overdose cases. A simple method for the quantification of low levels of nine nitazene analogs and brorphine in Dried Blood Spots (DBS) was developed and validated. 10 mu L of spiked whole blood is deposited on a Capitainer (R) B card and allowed to dry. The spot is punched out, and extracted with 500 mu L methanol:acetonitrile (3:1 v/v) added with 1.5 mu L of fentanyl-D5 as the internal standard. After stirring, sonication, and centrifugation of the vial, the solvent is dried under nitrogen, the extract is reconstituted in 30 mu L methanol, and 1 mu L is injected into a UHPLC-MS/MS instrument. The method validation showed linear calibration in the 1-50 ng/mL range, LOD values ranging between 0.3 ng/mL (isotonitazene) and 0.5 ng/mL (brorphine), average CV% and bias% within 15 % and 10 % for all compounds, respectively. The matrix effect due to blood and filter paper components was within 85-115 % while recovery was between 15-20 %. Stability tests against time and temperature showed no significant variations for storage periods up to 28 days. Room temperature proved to represent the best samples storage conditions. UHPLC-MS/MS proved capable to reliably identify all target analytes at low concentration even in small specimen volumes, as those obtained from DBS cards, which in turn confirmed to be effective and sustainable micro -sampling devices. This procedure improves the efficiency of toxicological testing and provides an innovative approach for the identification of the nitazene class of illicit compounds.
Method development for the quantification of nine nitazene analogs and brorphine in Dried Blood Spots utilizing liquid chromatography – tandem mass spectrometry
Ververi, Christina;Galletto, Martina;Massano, Marta;Alladio, Eugenio;Vincenti, Marco;Salomone, Alberto
2024-01-01
Abstract
The detection of nitazenes in biological fluids is increasingly needed as they are repeatedly reported in intoxication and overdose cases. A simple method for the quantification of low levels of nine nitazene analogs and brorphine in Dried Blood Spots (DBS) was developed and validated. 10 mu L of spiked whole blood is deposited on a Capitainer (R) B card and allowed to dry. The spot is punched out, and extracted with 500 mu L methanol:acetonitrile (3:1 v/v) added with 1.5 mu L of fentanyl-D5 as the internal standard. After stirring, sonication, and centrifugation of the vial, the solvent is dried under nitrogen, the extract is reconstituted in 30 mu L methanol, and 1 mu L is injected into a UHPLC-MS/MS instrument. The method validation showed linear calibration in the 1-50 ng/mL range, LOD values ranging between 0.3 ng/mL (isotonitazene) and 0.5 ng/mL (brorphine), average CV% and bias% within 15 % and 10 % for all compounds, respectively. The matrix effect due to blood and filter paper components was within 85-115 % while recovery was between 15-20 %. Stability tests against time and temperature showed no significant variations for storage periods up to 28 days. Room temperature proved to represent the best samples storage conditions. UHPLC-MS/MS proved capable to reliably identify all target analytes at low concentration even in small specimen volumes, as those obtained from DBS cards, which in turn confirmed to be effective and sustainable micro -sampling devices. This procedure improves the efficiency of toxicological testing and provides an innovative approach for the identification of the nitazene class of illicit compounds.File | Dimensione | Formato | |
---|---|---|---|
Ververi et al 2024 JPBA nitazens in DBS.pdf
Accesso aperto
Tipo di file:
PDF EDITORIALE
Dimensione
588.31 kB
Formato
Adobe PDF
|
588.31 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.