Robotic surgery has recently been used for treatment of renal cell carcinoma (RCC) and neoplastic thrombus located in the renal vein or inferior vena cava (IVC). Accurate identification of the thrombus location is crucial, and three-dimensional augmented reality (3D AR) may be valuable in achieving this. We enrolled patients with nonmetastatic RCC and level 0-I venous thrombus (Mayo Clinic classification) for robot-assisted radical nephrectomy and thrombectomy with 3D AR guidance. Five patients were prospectively enrolled; three had a level 0 thrombus and two had a level I thrombus. The mean operative time was 123 +/- 15 min, mean IVC clamping time was 9.4 +/- 6.8 min, and mean estimated blood loss was 750 +/- 150 ml. The AR system allowed precise estimation of the thrombus location in all cases. No intraoperative complications or postoperative Clavien-Dindo grade >2 complications occurred. Use of 3D AR guidance allowed correct estimation of the limits of the thrombus and guided the surgeon in selecting an appropriate surgical strategy.
Robotic Vena Cava Thrombectomy with Three-dimensional Augmented Reality Guidance
Amparore, Daniele;Checcucci, Enrico;Piramide, Federico;Busacca, Giovanni;Volpi, Gabriele;De Cillis, Sabrina;Sica, Michele;Verri, Paolo;Piana, Alberto;Fiori, Cristian;Porpiglia, Francesco
2024-01-01
Abstract
Robotic surgery has recently been used for treatment of renal cell carcinoma (RCC) and neoplastic thrombus located in the renal vein or inferior vena cava (IVC). Accurate identification of the thrombus location is crucial, and three-dimensional augmented reality (3D AR) may be valuable in achieving this. We enrolled patients with nonmetastatic RCC and level 0-I venous thrombus (Mayo Clinic classification) for robot-assisted radical nephrectomy and thrombectomy with 3D AR guidance. Five patients were prospectively enrolled; three had a level 0 thrombus and two had a level I thrombus. The mean operative time was 123 +/- 15 min, mean IVC clamping time was 9.4 +/- 6.8 min, and mean estimated blood loss was 750 +/- 150 ml. The AR system allowed precise estimation of the thrombus location in all cases. No intraoperative complications or postoperative Clavien-Dindo grade >2 complications occurred. Use of 3D AR guidance allowed correct estimation of the limits of the thrombus and guided the surgeon in selecting an appropriate surgical strategy.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S2666168324002532-main.pdf
Accesso aperto
Dimensione
1.09 MB
Formato
Adobe PDF
|
1.09 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.