Single ion counting in particle therapy may lead to new beam monitoring systems, enabling innovative delivery strategies that are faster and more sensitive than those currently used in clinics. Previous studies carried out by the University and the National Institute of Nuclear Physics (INFN) of Turin have demonstrated the feasibility of using thin silicon detectors to count single protons in clinical beams. The aim of this work is to report the performance of a strip-segmented 60- mu m thick silicon PIN sensor used for single carbon ion discrimination. All measurements were performed using the CNAO synchrotron at different beam energies covering the clinical energy range (115 -399 MeV/u). Signals from the sensor strips were read using a custom amplifier board and sampled with a 5 GS/s digitizer. The carbon ion signals were analyzed in terms of amplitude, duration, and deposited charge at different sensor bias voltages.

Monitoring of carbon ion therapeutic beams with thin silicon sensors

Montalvan Olivares, D. M.
First
;
Marti Villarreal, O. A.;Abujami, M.;Bersani, D.;Cirio, R.;Data, E.;Deut, U.;Donetti, M.;Ferrero, M.;Ferrero, V.;Ferro, A.;Milian, F. Mas;Medina, E.;Ranjbar, S.;Sola, V.;Vignati, A.;Sacchi, R.;
2024-01-01

Abstract

Single ion counting in particle therapy may lead to new beam monitoring systems, enabling innovative delivery strategies that are faster and more sensitive than those currently used in clinics. Previous studies carried out by the University and the National Institute of Nuclear Physics (INFN) of Turin have demonstrated the feasibility of using thin silicon detectors to count single protons in clinical beams. The aim of this work is to report the performance of a strip-segmented 60- mu m thick silicon PIN sensor used for single carbon ion discrimination. All measurements were performed using the CNAO synchrotron at different beam energies covering the clinical energy range (115 -399 MeV/u). Signals from the sensor strips were read using a custom amplifier board and sampled with a 5 GS/s digitizer. The carbon ion signals were analyzed in terms of amplitude, duration, and deposited charge at different sensor bias voltages.
2024
Inglese
contributo
1 - Conferenza
13th International Conference on Position Sensitive Detectors (PSD)
Oxford, ENGLAND
September 3 – 8 2023
Internazionale
Esperti anonimi
1063
1
4
4
https://www.sciencedirect.com/science/article/pii/S0168900224002158
Silicon sensors; Carbon ion therapy; Beamline instrumentation
BRASILE
1 – prodotto con file in versione Open Access (allegherò il file al passo 6 - Carica)
04-CONTRIBUTO IN ATTI DI CONVEGNO::04B-Conference paper in rivista
info:eu-repo/semantics/conferenceObject
24
open
Montalvan Olivares, D.M.; Marti Villarreal, O.A.; Abujami, M.; Bersani, D.; Camperi, A.; Centis Vignali, M.; Cirio, R.; Data, E.; Deut, U.; Donetti, M...espandi
273
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900224002158-main.pdf

Accesso aperto

Tipo di file: PDF EDITORIALE
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2008090
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact