An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.

The CGEM-IT readout chain

Amoroso A.;Bianchi F.;Bortone A.;Da Rocha Rolo M.;De Mori F.;Destefanis M.;Greco M.;Lavezzi L.;Maggiora M.;Marcello S.;Morgante S.;Rivetti A.;Sosio S.;Spataro S.;
2021-01-01

Abstract

An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.
2021
16
8
1
22
https://iopscience.iop.org/article/10.1088/1748-0221/16/08/P08065
Data acquisition circuits; Detector control systems (detector and experiment monitor-ing and slow-control systems, architecture, hardware, algorithms, databases); Front-end electronics for detector readout; Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc)
Amoroso A.; Baldini Ferroli R.; Balossino I.; Bertani M.; Bettoni D.; Bianchi F.; Bortone A.; Bugalho R.; Calcaterra A.; Cerioni S.; Chiozzi S.; Cibin...espandi
File in questo prodotto:
File Dimensione Formato  
Amoroso_2021_J._Inst._16_P08065.pdf

Accesso riservato

Descrizione: Articolo originale
Tipo di file: PDF EDITORIALE
Dimensione 4.99 MB
Formato Adobe PDF
4.99 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
2105.08979.pdf

Open Access dal 01/09/2022

Descrizione: Arxiv
Tipo di file: POSTPRINT (VERSIONE FINALE DELL’AUTORE)
Dimensione 4.6 MB
Formato Adobe PDF
4.6 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/1810158
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 8
social impact