Anthropomorphic digital phantoms can be a valuable tool for in silico testing and optimization of screening and diagnostics techniques. These can be leveraged for virtual clinical trials and for the generation of synthetic medical images, via computational models simulating the entire image acquisition pipeline. In this framework, we calculate realistic X-ray mammograms, using as an input 3D digital phantoms, reconstructed from sets of dedicated breast computed tomography (BCT) images from different patients [1]. After the application of ad hoc filters for reducing the level of noise in the source BCT images, we derive the phantom voxel-based structure and perform the segmentation into glandular, fat and skin tissues. To this aim, different approaches based on spline approximation or interpolation are compared, comprising the use of weighted essentially non-oscillatory (WENO) technique for handling sharp gradients and discontinuities [2]. To generate multiple phantoms from a single BCT scan, we also introduce geometrical transformations replicating breast shape deformities, and we locally add artificial lesions. After the simulation of phantom biomechanical compression, we model the X-ray interaction with breast tissues with a Monte Carlo approach to obtain synthetic mammograms with variable anatomical features. References [1] Oria M. et al. (2025) Image-based reconstruction of anthropomorphic breast phantoms for synthetic mammogram generation. Comput. Biol. Med., vol. 198, 111121. [2] Arandiga F., Remogna S. (2026) Approximation of piecewise smooth functions by nonuniform non- linear quadratic and cubic spline quasi-interpolants. Math. Comput. Simul., vol. 241, pp. 758-770.

Spline-Based Reconstruction of Digital Breast Phantoms for In Silico Medical Imaging

Alessandra Manzin
;
Chiara Andreis;Riccardo Ferrero;Marta Vicentini;Paola Lamberti;Sara Remogna
2026-01-01

Abstract

Anthropomorphic digital phantoms can be a valuable tool for in silico testing and optimization of screening and diagnostics techniques. These can be leveraged for virtual clinical trials and for the generation of synthetic medical images, via computational models simulating the entire image acquisition pipeline. In this framework, we calculate realistic X-ray mammograms, using as an input 3D digital phantoms, reconstructed from sets of dedicated breast computed tomography (BCT) images from different patients [1]. After the application of ad hoc filters for reducing the level of noise in the source BCT images, we derive the phantom voxel-based structure and perform the segmentation into glandular, fat and skin tissues. To this aim, different approaches based on spline approximation or interpolation are compared, comprising the use of weighted essentially non-oscillatory (WENO) technique for handling sharp gradients and discontinuities [2]. To generate multiple phantoms from a single BCT scan, we also introduce geometrical transformations replicating breast shape deformities, and we locally add artificial lesions. After the simulation of phantom biomechanical compression, we model the X-ray interaction with breast tissues with a Monte Carlo approach to obtain synthetic mammograms with variable anatomical features. References [1] Oria M. et al. (2025) Image-based reconstruction of anthropomorphic breast phantoms for synthetic mammogram generation. Comput. Biol. Med., vol. 198, 111121. [2] Arandiga F., Remogna S. (2026) Approximation of piecewise smooth functions by nonuniform non- linear quadratic and cubic spline quasi-interpolants. Math. Comput. Simul., vol. 241, pp. 758-770.
2026
Numerical Computations: Theory and Algorithms (NUMTA 2026)
Curinga (CZ)
21-27 giugno 2026
Numerical Computations: Theory and Algorithms NUMTA 2026
Society for Industrial and Applied Mathematics (SIAM
1
1
136
136
978-88-907488-4-4
https://numta.org
Breast digital phantoms; in silico imaging; spline methods
Alessandra Manzin, Martina Oria, Chiara Andreis, Riccardo Ferrero, Marta Vicentini, Paola Lamberti, Sara Remogna
File in questo prodotto:
File Dimensione Formato  
book-NUMTA2026.pdf

Accesso aperto

Descrizione: Volume NUMTA 2026
Tipo di file: PDF EDITORIALE
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2318/2170911
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact